NOTE
Some settings cannot be changed until five (5) minutes has
elapsed after the dive.
5.8.1. Setting the gases
If set to the MIXED mode, the correct oxygen and helium percentages of the gas in
your cylinders (and additional gases) must always be entered into the dive computer
to ensure correct tissue and oxygen calculation. In addition, the oxygen partial pressure
limit must be set. You can either modify the dive plan with the Suunto Dive Planner
or enter the correct values directly into the dive computer after analyzing the gas mixes
in your cylinders.
When in the MIXED setting mode, the equivalent maximum operating depth, based
on the chosen setting, is also be displayed.
After entering values for Mix1, you can set additional mixes, Mix2–Mix8, similarly. You
can set them to "PRIMARY", "SECONDARY" or "OFF". Mix1 is always set as a primary
gas.