84
ENGINE NOT RUNNING
– Vertical position –
1. Make sure that the motor is stopped.
2. Remove the plug A or C from the flushing
port.
3. Install garden hose by using a hose connec-
tor matched to flushing port thread B.
Thread B: 0.75 – 11.5 NHR (American stan-
dard hose coupling threads for garden hose
applications.)
NOTE:
The hose connector (flushing attachment)
matched to the flushing point thread B is
included in the crate parts.
4. Turn on the water to obtain a good water
flow. Flush the engine for about five minutes.
5. Turn off the water.
6. Remove the hose and connector (if used)
then reinstall the plug into the flushing port.
7. Leave the motor in a vertical position until
the engine is drained completely.
ENGINE NOT RUNNING
– Full tilt up position –
1. Raise the engine to the full tilt up position.
2. Follow the “ENGINE NOT RUNNING – Verti-
cal position” instructions.
DO NOT RUN ENGINE IN THE FULL TILT
UP POSITION.
3. Lower the motor to a vertical position until
the engine is drained completely.