EasyManua.ls Logo

Suzuki DF300BMD - Page 98

Suzuki DF300BMD
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
98
4. Remove the sub battery cable fuse.
5. Inspect the fuse and replace with new fuse if
needed.
NOTE:
If a fuse is blown, try to determine the root
cause and correct it.
If the cause is not corrected, the fuse may be
blown again.
V
WARNING
If you replace a blown fuse with a fuse having
a different amperage rating or with a substi-
tute such as aluminum foil or a wire, extensive
electrical system damage and a fire may
result.
Always replace a blown fuse with a fuse of the
same type and rating.
Sub battery cable
fuse case
Normal fuse
Main fuse (60 A)/
Isolator fuse (40 A)
Blown fuse
Normal fuse
Blade type fuse
Blown fuse
NOTICE
If a new fuse blows in a short time after instal-
lation, you may have a major electrical system
problem.
Consult your SUZUKI marine dealer.
Fuse box cover