6-18 ELECTRICAL SYSTEM
If the peak voltage measured on the CDI unit coupler is lower
then the standard value, measure the peak voltage on the
pickup coil coupler as follows.
•Disconnect the pickup coil coupler
•Connect the multi circuit tester (DM 200) with the peak volt
adaptor as follows.
+ Probe: Blue with yellow tracer lead wire
- Probe: Green with white tracer lead wire
Measure the pickup coil peak voltage in the same manner as on
the CDI unit coupler.
W
Tester knob indication : voltage ( v )
Pickup coil primary peak voltage : More then 4 V
\
Multi circuit tester set (DM 200)
If the peak voltage on the pickup coil coupler is within specifica-
tion, but on the CDI unit coupler is not within specification,
replace the wire harness with a new one. If both peak voltage
are out of specification, replace the pickup coil with a new one.
PICKUP COIL RESISTANCE
•Remove the right side frame cover.
•Disconnect the generator coupler
Measure the resistance between the lead wire using the multi
circuit tester(DM 200). It the resistance is not within the specified
value, the pickup coil must be replaced.
\
09900-25002: Pocket tester
Tester knob indication: Resistance (Ω)
V
Ignition coil resistance: 180 - 280 Ω
(Blue with yellow - Green with white)