6. OPERATION:
Operate as one unit:
Place the compressor unit on a level surface.
Put the haze unit on top of the compressor.
Lock the two butterfly catches (one in front, one at the back of the machine). Ensure the catches are
properly locked.
Use the short air tube & cable set 0,5 m (20”).
Operate as separate units:
Place both units on level surfaces, especially the haze unit, which will not work properly if it is not
placed on a level surface during all times.
Use the long air tube & cable set 10 m (33 ft). Or, as an option, the 16 m (53 ft) or 25 m (83 ft) air
tube.
If the air tube length exceeds 10 m (33 ft), an extension electric cable must be used. The haze unit
contains a fan as the only electrical component, and the power consumption is very low (approx. 40
watts). The hazer can also be directly connected to a mains outlet, but on / off of the fan will not be
automatically controllable from the compressor unit. NOTE: Always remember to switch the haze unit
fan off when the machine is not in operation. If not, great amounts of dust will enter the hazer, and the
lifetime of the fan will be reduced. NOTE: The fan must be in use when the compressor unit is on. If
not, haze will not be produced.
The hazer’s fan speed can NOT be regulated with a dimmer. If the haze unit is connected directly to a
mains outlet, and not to the compressor unit, ensure the mains outlet is on or off only. Use of a dimmer
will damage the fan motor, and warranty will be void.
D
MX control panel
Standard control panel
Standard control panel:
1. Mains fuse (slow
blow) 115V: 8 Amp.
230V: 4 Amp.
2. IEC mains inlet
3. Mains switch
DMX control panel:
4. DMX address 100´s
5. DMX address 10´s
6. DMX address units
7. DMX operate LED
8. XLR DMX out
9. XLR DMX in
10. Mains fuse (slow
blow) 115V: 8 Amp.
230V: 4 Amp.
11. IEC mains inlet
12. Manual override
switch (set to ”1” for
manual on/off,
without DMX control)
13. Mains switch