9
USE ORIGINAL SWEFOG AIR TUBES & AIR TUBE FITTINGS ONLY. USE OF ANY OTHER
TUBES OR FITTINGS, MAY DAMAGE THE COMPRESSOR, AND VOID THE WARRANTY.
NEVER USE MORE THAN ONE AIR TUBE FOR CONNECTION BETWEEN THE
COMPRESSOR & HAZE UNIT.
NEVER USE AIR TUBES WITH DIFFERENT INNER DIAMETER SIZE.
The maximum length depends on the tube size used:
ID 8 mm (included with the machine): 10m (33 ft).
ID 10 mm (optional): 16 m (53 ft).
ID 12 mm (optional): 25 m (83 ft).
Do NOT – under any circumstances – exceed 25 m length. Always use the shortest possible tube length. A
long tube will cause losses in air pressure, which will decrease haze output capacity.
NEVER OPERATE THE HAZE UNIT WITH OTHER COMPRESSED AIR SOURCES.
Other types of compressed air installations are usually supplied by a compressor with oil lubrication. Small
quantities of the lubricating oil will be added to the air, and enter the hazer, damaging the parts inside.
Great difficulties of regulate the precise amount of air flow and air pressure will increase the risk of
underload or overload of the haze unit, which will result in “wet” haze or a damaged hazer.
WARRANTY IS VOID, IF THE HAZER IS MODIFIED OR OPERATED WITH ANY OTHER
COMPRESSED AIR SOURCE THAN THE U 300 COMPRESSOR UNIT.
Normal operation:
NOTE: When the machine is switched off, wait minimum 1 minute before it is switched on again. If not,
the high starting current of the compressor motor may cause the mains fuse to blow.
• Place the machine on a level surface.
• Remove the fill cap on top of the machine. Fill with original “Swefog Ultimate” fluid. Fill slowly. DO
NOT overfill. NEVER exceed the ”max” fluid level. Close the fill cap before switching on the
machine.
• NEVER fill fluid when machine is in operation.
• Connect a suitable air tube and an electrical cable between the compressor and haze unit.
• The machine is continuously cooled by several fans and an intercooler and can operate without
interruptions as long as there is mains power and fluid supply.
• Operating the machine with an empty fluid tank does not damage the machine.
• Connect a mains cable to a suitable mains outlet: [120V min. 10 Amps capacity], [230V min. 5 Amps
capacity]. NOTE: Due to the high starting current, the machine consumes approx. 4 times its regular
power consumption at the moment it is switched on. Always use mains fuses of the slow-blow type.
OPERATION - Standard model without DMX control:
• The machine is switched on / off with the mains switch.
• The haze output is regulated by the running time of the machine. The longer it operates, the more haze
is produced.
!
CAUTION !