SWF E-U1201 - Failure to Detect Trimming and Return; Short Remaining Upper Thread After Trimming

Default Icon
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
Failure to Detect
Trimming and
Return
Short Remaining
Upper Thread
After Trimming
① Poor connection of the
sensor connector
② Bad board
③ Faulty sensor and wrong
position of the return sensor
controller body
① Failure to separate the
upper thread since the entry
of the moving blade is too
fast or slow
② Inappropriate distance
between the moving blade
and the rotary hook
③ Inappropriate location of
the picker
④ Faulty operation of the
picker
■ Check the status of the
connector connection
■ Replace the board on the
rear side of the controller
box
■ Replace the sensor
■ Remove the foreign
materials around the sensor
■ Adjust the location of the
return sensor controller
body
■ Adjust the initial position of
the moving blade
■ Adjust the distance between
the moving blade and the
hook
■ Adjust the location of the
picker
■ Check the fuse on
the front side of the
controller box and replace it
■ Check the solenoid
connection terminal and
replace the solenoid
■ Check the connector
connection status and
replace the board on the
rear side of the controller
box
■ Check the rated
voltage of the fuse
1) For 3-phase
: 250V 15A
2) For 1-phase
: 250V 15A
Corrective Action and Check PointCause of TroubleType Remarks