SWF E-U901 - Failure to Detect Trimming and Return; Short Remaining Upper Thread After Trimming

Default Icon
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
Failure to Detect
Trimming and
Return
Short Remaining
Upper Thread
After Trimming
Poor connection of the
sensor connector
Bad board
Faulty sensor and wrong
position of the return sensor
controller body
Failure to separate the
upper thread since the entry
of the moving blade is too
fast or slow
Inappropriate distance
between the moving blade
and the rotary hook
Inappropriate location of
the picker
Faulty operation of the
picker
Check the status of the
connector connection
Replace the board on the
rear side of the controller
box
Replace the sensor
Remove the foreign
materials around the sensor
Adjust the location of the
return sensor controller
body
Adjust the initial position of
the moving blade
Adjust the distance between
the moving blade and the
hook
Adjust the location of the
picker
Check the fuse on
the front side of the
controller box and replace it
Check the solenoid
connection terminal and
replace the solenoid
Check the connector
connection status and
replace the board on the
rear side of the controller
box
Check the rated
voltage of the fuse
1) For 3-phase
: 250V 15A
2) For 1-phase
: 250V 15A
Corrective Action and Check PointCause of TroubleType Remarks