FITTED EQUIPMENT
114
Fuses 12 V
The fuse is in the electronics beneath the
connection cover. Replace the unit’s fuse only
with an identical fuse.
Device fuse: 10 A – slow – (T 10 A)
Fuses 230 V
The fuse and the power supply lines must only
be replaced by an expert! The unit must be
disconnected from the mains (all poles) before
opening the electronic housing lid.
The fuse is in the power electronics (16)
beneath the electronic housing lid.
This fine fuse must always be replaced with a
fuse of the same type: 10 A, slow, interrupting
capacity “H”.
Overheating protection 230 V
The 230 V heating facility has a mechanical
overheating switch. If the 12 V power supply
is interrupted during operation or during the
after-run period, for example, the temperatures
within the unit could activate the overheating
protection. To reset the overheating protection,
allow heater to cool, remove connection cover
and press red reset button.