EasyManuals Logo

Swift Sterling User Manual

Swift Sterling
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
FITTED EQUIPMENT
126
Electric Heating
Check that 230v supply is displayed on
the Standby Screen. The Alde boiler is
programmed to use power economically and
there are times when it may use no power at
all, even if set to 3kW.
i. Select Off, 1, 2 or 3 kW electric heating.
More power equals better performance, but
may be restricted by the current (amps) limit
on the electric hook-up.
ii. Adjust by pressing Plus or Minus button.
Max current draw from 230 V supply is 4.5
A on 1 kW, 9 A on 2 kW, 14 A on 3 kW. If
the electric supply has unstable voltage, the
amperage will also fluctuate.
Gas Heating
The Alde boiler is programmed to use power
economically. The gas burner has two stages,
shifting dynamically between low or full flame.
There are times when it may use no power at
all, even if gas heating is selected.
i. Press the Flame button to select gas heating.
Green is on, blue is off.
Use both gas and electric heating for best
performance.
4. Shutting down the system
To save energy, the control panel only updates
the boiler after the last adjustment is made.
Wait 10 secs before shutting down the system
to ensure the boiler is updated.
Press the Power button again. The screen
goes dark, the green LED is unlit. The system
is off.
5. Setup
Most UK installations do not need setting up
in the Settings Menu, and use default factory
settings.
Restore default factory settings
Before using the system for the first time,
restore default factory settings. Your control
panel may have been tested by the dealer or
installer, and some settings may have been
changed.
i. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
ii. Press down arrow, until Reset button is
displayed.
iii. Press the Reset button to proceed
>
Setup expansion tank pump
To use the 12 V circulation pump in the
expansion tank, you must set it up. This is not
a default factory setting.
Note: Under factory settings, the system
will use the 12 V inline circulation pump by
default.
i. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
ii. Press down arrow, until Circulation Pump
button is displayed.
iii. Press Circulation Pump button, select
Expansion Tank Pump to proceed.
> >
Setup Antimicrobial function
To actively kill Legionella, setup the
Antimicrobial function. At 2:00 every night,
the hot water will be heated to over 65°C
for 30 mins. This further reduces the risk of
Legionella.
i. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
ii. Press down arrow, until Antimicrobial button
is displayed.
iii . Press Antimicrobial button to proceed.
>
ALDE HEATING OPERATING INSTRUCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swift Sterling and is the answer not in the manual?

Swift Sterling Specifications

General IconGeneral
BrandSwift
ModelSterling
CategoryCaravans
LanguageEnglish

Related product manuals