FITTED EQUIPMENT
128
Trouble shooting
Any error messages will be displayed on the
Standby Screen. Error messages can be
cleared by switching off 12 V supply to the
boiler for 10 secs.
The system is completely dead,
the control panel is blank
Check the 20 mm T3.15 Amp glass fuse in
the boiler. This is located under the lid of the
black plastic service hatch, in a green plastic
fuse holder.
Check the 12 V supply to the boiler, it should
be above 12 V.
Check the 12 V cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
“Panel failure 1” & “Panel failure 2”
Moisture is trapped in the control panel.
Remove the Alde control panel from
the vehicle and air in a warm, dry place
overnight.
“Gas failure”
• Out of gas or gas is not igniting.
Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
“Overheat red fail” or “Overheat blue fail”
• Bleed the system of air.
Check the fluid level in the expansion tank. It
should be 1 cm above Min mark when cool.
• Check the circulation pump is responding.
• Wait 15 mins for the fluid to cool down.
“Overheat PCB”
Failsafe in boiler has triggered.
It should be 1 cm above the Min mark when
cool.
Check the boiler compartment is ventilated,
and that the vents are unobstructed. Do not
place stowage in the boiler compartment.
“Fan failure”
Combustion fan speed too low. Bearing may
be stiff after a period of disuse.
Automatically clears after 5 mins. Please try
again.
“Connection failure”
Loose connection between Alde control
panel and boiler.
Unplug cable at the control panel and boiler,
then carefully plug back in.
Check there is slack on the cable at the
control panel, but not excessive weight from
free-hanging/unmanaged cable.
“Window open”
Optional window sensor has triggered, gas
heating is suspended. Automatically clears
and gas heating resumes when window is
closed.
“Connection fail ext”
Break in comms between Alde control panel
and daisy-chained third party control panel.
Check the cable between the Alde control
panel and third party control panel.
“Low battery”
12 V supply to boiler has dropped below
10.5 V, possibly causing system brownout.
Automatically clears when 12 V supply
reaches 11 V.
“No match Heater/Panel”
Control panel is incompatible with boiler
PCB.
Check control panel part number. Control
panel 3020-013 is for 3020 A-series boiler,
3020-113 is for 3020 HE-series boiler.
If problems persist, please contact Alde, or
your dealer or installer.
For our frequently asked questions, or
download all instruction manuals, please visit
our web site at: www.alde.co.uk
ALDE HEATING OPERATING INSTRUCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swift Sterling and is the answer not in the manual?

Swift Sterling Specifications

General IconGeneral
BrandSwift
ModelSterling
CategoryCaravans
LanguageEnglish

Related product manuals