EasyManua.ls Logo

Swift Sterling

Swift Sterling
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FITTED EQUIPMENT
156
Failure: The refrigerator does not cool in
230 V operation.
Possible cause Action you can take
On-board fuse defective Fit new fuse
Vehicle not connected to mains supply
voltage
Make a connection to a mains power supply
AES: Gas operation despite connection to the
mains supply voltage?
Appliance switches to gas operation due to
insufficient mains supply voltage (automatically
switches back to 230 V operation)
Heating element defective (please refer to
failure indication
Please inform Dometic Customer Services
Information on failure display and
trouble-shooting
Refrigerators with an electronics system
(MES, AES) indicate the occurence of a
malfunction by the LED or display flashing.
If a malfunction occurs, the indicator LED
“Failure” (8) flashes simultaneously. In the
case of AES models an acoustic alarm
sounds.
Before notifying the authorised Service Center,
please check whether:
the instructions in section “Operating the
refrigerator” have been observed.
• the refrigerator stands level.
it is possible to operate the refrigerator with
any available power source.
Status indicators
MES
Fig. 51
1 2 3 4 6 7 8
1 - Button ON / OFF
2 - Energy selector switch 230 V AC
3 - Energy selector switch GAS
4 - Energy selector switch 12V DC
6 - temperature level button
7 - temperature level display
8 - fault LED / GAS FAULT reset button
DOMETIC REFRIGERATOR TROUBLESHOOTING

Table of Contents

Related product manuals