ELECTRICS
92
3.8 Common Fault Table
Reverse Polarity
light is illuminated
on PSU
Generator being used ‘The Reverse Polarity warning light is
on when using my Generator’. This is
a normal side effect when using some
types of generator. Instead of con-
necting the neutral conductor to earth,
some generators centre tap the earth
connection making both neutral and
live conductors 110v above earth. This
110v difference causes the neon polarity
indicator to illuminate. In most cases it is
still safe to use the generator, but please
consult the generator handbook for
further information.
Control Panel
Problems
Control Panel has no display Check batteries and fuses, turn PSU
shutdown switch and charger switch on
and ensure mains supply is connected.
Check control panel connecting lead at
PSU and behind Control Panel.
Contact your Dealer
12v Power turns off Battery protect feature has operated to
protect the Vehicle battery and or the
Leisure battery. See 3.4C
Engine has been started, all equipment
has been disconnected to meet EMC
requirements. See 2.7
Control Panel locked /
erratic function
Observe control panel handling instruc-
tions
Control panel software may have
crashed. Reboot control panel by turning
off the PSU isolate switch. Wait 30 sec-
onds then turn the switch back on.
POWER CONTROL SYSTEM FAULTS