SeceuroGlide Operating & Maintenance Guide
*Bottom slat transmitter battery is a CR2430 battery.
**Hand transmitter battery is a CR2430 battery.
Trouble Shooting
Fault Possible Cause Solution
Lock will not
engage
The lock is not correctly
aligned with the lock hole.
Apply more pressure to the bottom of the curtain until the lock engages
or move the curtain around slightly until it is in the correct position for
the lock(s) to engage.
Lock has become
loose.
The screws holding the lock
to the door have begun to
unfasten.
Check and tighten the two screws fastening the lock to the door.
Manually Operated Products
LED Status
Off Standby
Slow flashing Waiting for an input/adjustment
Rapid flashing Deactivation/activation in progress
Constantly on Installation fault/failure
Electrically Operated Products
Fault
LED Status
Possible Cause Solution
No door
movement.
Motor wired incorrectly.
The motor thermal
protection has activated.
Wait for the motor to cool down (10 minutes).
Waiting for motor
adjustment.
Motor limit positions need setting.
Please contact the installer.
Door opens OK.
Door closes in
dead man mode.
Optical wired safety
edge failure.
Radio safety edge failure.
Please contact the installer.
Door opens OK.
Door closes in
dead man mode.
Radio interference.
If a powerful radio system is present close by
and is transmitting on the same frequency, the
receiver may be experiencing radio interference.
Check if any wireless systems are present within
the area.
Door opens OK.
Door closes in
dead man mode.
The safety edge
transmitter batteries
have expired.
Replace the bottom slat safety edge transmitter
battery.*
The door has
stopped due to
an obstacle.
Obstacle detection.
Check for obstacle interference with the safety
edge strip or photocell.
Hand transmitter
not working.
Hand transmitter
batteries flat.
Change hand transmitter battery.**