DOC 6511_Release K
ATS-6511A/B/C Users Guide
43
[format] B
[signal_word] 120
[type] irig
[4]
[epoch_127] false
[format] B
[signal_word] 120
[type] irig
[node]
[maintenance_mode]
[enable] false
[system_autoswitching_participant] true
[pps_adjust]
[distribution_delay] 0.000000000000000e+00
[ptd_port]
[averaging_interval] 10
[reference]
[external]
[type] cesium
[source] ocxo
[timescale]
[smcp]
[syscfg]
[mode] standalone
[OK] 2013-08-13T18:45:56Z
P. At this point if there are no alarms the ATS-6511 is functioning properly. Network
connectivity should be checked to ensure that data is being transmitted properly.
Q. If operations are normal and the setup is proper type save at the command prompt to
save the system default settings or save filename to save the settings to a different
configuration file.
Note: If you do not save the user default settings the system will come up with the factory
default values the next time the system reboots.