DOC 6511_Release K
ATS-6511A/B/C Users Guide
69
[when] 1998-01-01-00:06:52.834
[remote_tdc_starvation] Issues with the data exchange over fiber
[active] false
[cleared]
[what] Receiving remote TDCs
[when] 2011-11-07-17:11:01.316
[occurrences] 1
[set]
[what] Not receiving remote TDCs
[when] 2011-11-07-17:10:39.722 [syscfg]
[active] false
[occurrences] 0
[syscfg]
[active] false
[occurrences] 0
[tcxo_failure] Internal Clock Failure
[active] false
[occurrences] 0
[input] Fiber Status
[switch] Auto Switch: A Auto Switching in ON, Fiber A = Master
[kas2] KAS2 Data
[phase_step_count] 2
[phase_sync_count] 1
[ptd] 9.497872340000000e-09 Estimated UTC Offset
[outputs]
[enabled] true
[reference] 6511B only
[frequency]
[external]
[communications] bad
[locked] false
[signal] missing
[hp5071]
[can_communicate] false
[lns]
[locked] true
[ocxo_freq_control] 1
[reference_frequency_estimate] Not Ready [time] 2011-11-07-18:07:56
[unit]
[network] Current network settings
[MAC] 00:A0:69:00:00:F8 Unit MAC Address
[broadcast] 192.168.150.255 Current Broadcast IP
[default_gateway] 192.168.150.1 Current Gateway Address
[ip] 192.168.150.71 Current IP Address
[netmask] 255.255.255.0 Current Subnet mask
[serial_number] 164233 Unit S/N
[start] 2011-06-09-21:21 Unit Start up (Date/Time Set)
[uptime] 18 hours, 38 minutes, 16 seconds Amount of time 6511 has been running
[ver] tflex-5-1-0 Current Software Version
System Errors: Alarms and events on the ATS-6511 are available via the status command. As
the events occur the system will set the alarm and time. Once the condition clears the system will
indicate the condition cleared, what the condition was, when it cleared and increment the
occurrence counter.
[clock_wander]
[active] false
[cleared]
[what] Clock wander is less than 100.000000ns