Attention
In case of multiple drive connection, ensure that the output driver has sufficient current driving
capability.
1.6.3.2 Connection diagram for the brake
Attention
Phase D can’t be used for connecting a brake when Node Safety is used:
use the safety brake connector of the safety circuit (SBC out) instead of phase D of the drive
circuit.
ensure to connect the brake GND signal to the Brake- signal of the safety circuit (SBC out)
instead of the general GND.