1.3.2.6 SOMANET Node Safety (Original
instructions)
SOMANET Node Safety provides two drive integrated safety functions according to IEC 61800-5-2:2017 as a
pure hardware solution
1. STO (Safe Torque Off) prevents the creation of torque in the motor and enables an uncontrolled stop in
accordance with stop category 0 of IEC 60204-1.
2. SBC (Safe Brake Control) provides a switchable (PWM) voltage output (0 V - U_bus) to directly and safely
control an external motor brake.
Attention
SOMANET Node Safety safely inhibits currents to the motor and to a brake when STO-SBC command has
been given (e.g. from an emergency stop device).
When the command has been released (e.g. manually resetting the emergency stop device) the currents
are allowed to be carried to the motor and to the brake.
The safety system must be designed to meet the requirement “restarting the machinery after a
stoppage must be possible only by an intended actuation of a control device provided for the purpose”.
Specifications of the safety functions
Setup of the safety functions
Using the safety functions
Examples for realising safety functions
Commissioning and maintenance
Changelog of the safety-related documentation
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 261/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node 1000 and is the answer not in the manual?

SYNAPTICON SOMANET Node 1000 Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node 1000
CategoryServo Drives
LanguageEnglish

Related product manuals