Beep Time after
Power on
Description
0 Sec Walk switch abnormal
30SEC Heat sensor abnormal
60Sec Walk motor abnormal
Error description : 0 sec --
Walk switch abnormal
Is the connector of walk switch on
main PCB surely connected?
Reconnect the connector
Yes
No
Is the connector between the cable
surely connected(Figure A)?
2.Error code number list
The console won’t show error , but we can identify the issue by gap time after
power on
Yes
No
Replace the main PCB
Reconnect the connector
Does the switch both stuck(Figure
B/C)?
Yes
Release or replace the
switch
No
Figure A
Figure B
Figure C