3.4. Pairing with di󽗈erent SKUs (X1 pairing with X1, or X1 pairing with X2, etc.)
X1 is set as the Master by default, while X2 and above models are set as the Master plus
several remotes.
Before pairing with other SKUs, please set the role for each headset. A communication group
can only have 1 Master.
For example:
X1 pairing with X1
Since X1 is set as the Master by default, please set another X1 as the remote or Connection
Level 1 then start pairing.
X1 pairing with X2
Set the X1 as the remote or Connection Level 1 then start pairing with X2.
Or set the Master of X2 as the remote or Connection Level 1 then start pairing with X1.
3.5. FAQ of Pairing
Q 01.
Q 01.
A 01.
A 01.
If a paired Connection Level 1 is mistakenly set as the Master or Connection Level 2 and
disconnects with the entire group, how to reconnect with the group?
If Connection Level 2 suddenly disconnects, how to reconnect?
Power all headsets except the Master and the headset that is needed for pairing. Set it
as the Connection Level 1 and pair it with the Master. After successfully pairing, restart
these 2 headsets and turn on all headsets to resume use.
There are 3 ways to reconnect:
1. Moving towards to the paired Connection Level 1 until it automatically reconnects.
2. Restart it and it will automatically connect to the paired Connection Level 1 once it is
turned on. However it requires the following conditions:
a. The Master has not switched the Boost Mode to mode 2 or mode three.
b. 2 headsets are within the signal reception range of pairing.
3. Long press the button B of the Connection Level 2 for 3 seconds to hear the 󽗉rst
"beep," then release, the voice prompt will play "Connecting and Pairing". The
Connection Level 2 will search for the nearby Connection Level 1 and pair with it.
*If the nearest Connection Level 1 is already paired with 2 Connection Level 2, the