14
Above Counter Installation Procedure
Install after stop water supply.
Caution
1
Please assemble the faucet top
(water top) and the diverter valve as
shown above.
3
Push in and fasten the 1/4” Hose
hose in "Figure 2" into the water
inlet at the bottom of the machine.
4
After finishing the connection of
"Figure 4" open the water supply
valve and adjust the water pressure.
2
Connect 1/4” Hose hose to the
adaptor in "Figure 2"
[Figure 1]
Diverter valve
[Figure 3]
[Figure 4]
[Figure 5]
5
Check the leaks on all connections
after installation is completed.
[Figure 2]
1/4” Hose
inlet
How to Install
Diverter valve