Doc003317.png
5) Fit the shaft of the piston (02) into the
mounting tool (T2).
6) Place the calibration sleeve (T1) into
the bore in the cylinder housing (01).
7) Insert the piston (02) with the mounting
tool (T2) through the calibration sleeve
(T1) into the cylinder housing (01).
8) Insert the guiding element (8.5) into the groove of the gasket locator
cover (4).
Doc003318.png
9) Install the seals of the gasket locators (03).
8.1 Back up ring
8.2 Rod seal
8.3 O-ring seal
Doc003338.png
10) Install the gasket locator covers (04) into the gasket locators (03).