EN
Master Language is English Hot Runner System Installation Guide SVC-17-0001_EN-Rev11
RESTRICTED: Property of Synventive. - 399 - All rights reserved. Errors and omissions excepted
For limited third party distribution based on need and intended use. © 2019 Synventive Molding Solutions
H O T R U N N E R T E C H N O L O G Y
Hot Runner System Installation Guide
Service and Maintenance / Single Axis Valve Gate Nozzle 16SVH
Mounting of the Thermocouple
NOTICE
For dismounting and mounting the thermocouple there is not
a need to have the cylinder housing dismounted.
1) Guide the thermocouple (22) through the heater band (14) into the
thermocouple hole of the head body (23).
Doc007380.png
2) Bring the clamping device (25) to vertical position.
3) Fix the thermocouple (22) with the hexagon socket cap screw (24).
Doc007431.png
Doc007272.png
4) Align the thermocouple (22) in the
nozzle heater (14) direction.
5) Fix the thermocouple (22) with heat
resistant adhesive tape at the outlet of
the nozzle heater (14).
6) Guide the thermocouple (22) into the thermocouple hole of the head
body (23).
7) Mount the heater band (10).
8) Complete the nozzle 16E-04.
NOTICE
Follow the heater mounting procedure of the nozzle 16E-04.