Master Language is English Hot Runner System Installation Guide SVC-17-0001_EN-Rev13
RESTRICTED: Property of Synventive. - 92 - All rights reserved. Errors and omissions excepted
For limited third party distribution based on need and intended use. © 2021 Synventive Molding Solutions
H O T R U N N E R T E C H N O L O G Y
Hot Runner System Installation Guide
Service and Maintenance / Actuator HB Series
3) Lift the entire actuator housing (A) out of the
assembly. Removal of the cooling plate (B)
is not required when removing the actuator
housing assembly.
Doc006356.png
4) Unscrew and remove the M6 socket head
cap screws (R).
5) Lift out the mounting plate (S).
Doc006357.png
8.1.1.7 Seal Replacement
Disassembly
1) Remove Snap Ring (A).
LETTER PART
1.1 Piston Seal
1.2 Guiding Element
1.3 O-Ring Seal
1.4 Rod Seal
1.5 Retaining Ring
1.6 Restrictor