Systec DX-45 - User Manual

Default Icon
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
S
ERVICE
M
ANUAL
S
YSTEC
V/D
S
ERIES
0
51
-X
V
051
-XD
Systec GmbH
Konrad-Adenauer-Straße 15
D-35440 Linden, Germany
Tel.: +49(0)6403 67070-0
Fax.: +49(0)6403 67070-222
01.01.2015
Revision: 2.1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Systec DX-45 and is the answer not in the manual?

Summary

1 Notes on the Documentation

1.2 Safety Instructions

Details essential safety instructions to be observed during operation and maintenance.

2 Commissioning

2.2 Device Connections

Details the various device connections for different models like VX/VE, VB, DX-23, DE-23, DB-23, etc.

2.9 Setting Parameters

Explains how to set various parameters using access levels and codes.

2.10 Instructing the Operating Personnel

Guides on how to instruct operating personnel on device functions and safety.

3 Mechanical Assemblies

3.3 Door Lock

Details the principle, closing, opening, and emergency opening procedures for the door lock.

3.8 Steam Generation

Explains steam generation methods and maintenance for steam generators and electrodes.

3.10 Internal Compressed Air System

Details the air compressor, pneumatic assembly, and related maintenance tasks.

5 Regular Tests and Maintenance

5.1 Regular Tests and Maintenance

Outlines regular maintenance tasks, referencing detailed sections for specific procedures.

5.2 Calibration and Adjustment

Explains the process of calibrating analogue inputs using service software or the control unit.

6 Service Software

6.1 Available Service Software

Introduces available service software, system requirements, and installation procedures.

6.2 Systec Service Software

Explains how to start the software, set communication parameters, and establish a connection.

6.2.5 Download Main

Details how to overwrite firmware on the digital circuit board using S19 files.

6.2.7 Calibration

Explains how to modify the calibration of analogue device inputs using the software.

6.2.10 Parameters

Explains how to view and modify device parameters, including program and global settings.

7 Troubleshooting

7.1 Reset

Provides instructions for resetting the controller software at atmospheric chamber pressure.

7.3 Troubleshooting

Contains troubleshooting diagrams for various system start issues.

7.3.14 Error Message: Sensor Error

Covers troubleshooting sensor errors, checking values, gain/offset, and analogue boards.

8 Parameters

8.2 List of Parameters

Provides a comprehensive list of device parameters, their descriptions, access levels, and ranges.

Systec DX-45 Specifications

General IconGeneral
Chamber Volume / Capacity45 liters
DisplayDigital display
TimerYes
Power Supply230 V / 50-60 Hz
Control SystemMicroprocessor-based PID controller