TROUBLE SHOOTING MS5 and MS7
Fault
Cause
No water or insufficient water at the
nozzle when rinsing
Function selector is in closed
position
Insufficient water supply to the unit
Valve at the end of the hose not
open
The unit does not suck up detergent
Function selector is not in the
correct position
Suction filter or chemical restrictor
are blocked by chemical residue
Water pressure is too low
Suction filter is above the fluid level
in chemical container
Poor foam quality
Chemical product is not a foaming
product
Incorrect dosing
Suction filter or chemical restrictor
are blocked by chemical residue
Water pressure is too low
Air pressure too low
Non-original foam nozzle fitted
Fault
Cause
Rinse pressure too low
Pump station not started
Too many simultaneous users
Pump stopped due to inlet pressure
less than 1.5 bar (23 psi)
The device will not start
Valve in inlet or outlet closed
Inlet water pressure less than 1.5
bar (23 psi)
TROUBLE SHOOTING PS1, PS3, PS5 and PS7
Fault
Cause
Rinse pressure too low
Pump station not started
Too many simultaneous users
Pump stopped due to inlet pressure
less than 1.5 bar (23 psi)
The device will not start
Valve in inlet or outlet closed
Inlet water pressure less than 1.5
bar (23 psi)