Safety precautions and safety devices must comply with national regulations applicable at any time.
Internally, protection corresponds to IP 55. On a number of components hazardous voltages can occur. During
operation the cabinet must always be closed.
Never insert or remove a plug from an electrical socket unless the power has been switched off.
System Cleaners low-pressure systems may only be used in conjunction with soaps and chemicals that are approved
for cleaning within the food or transport industries.
Soaps and chemicals that are classified as highly corrosive, toxic or which pose a health risk to humans or animals
may not be used.
The system must not be used together with solvents or volatile liquids that pose a health risk or are inflammable.
In the event that the system is used with non-approved soaps, chemicals or solvents, System Cleaners A/S disclaims
all liability.
If in doubt, please contact your soap or chemical supplier and read the supplier manual.
In the event that you use the system with chemicals that require mandatory labelling, or if the water temperature
exceeds 50°C, a low-pressure gun with an automatic closing device must be used.
Start
The system starts automatically in the event of falling pressure in the outlet pipe like when the operator opens the low
pressure gun or valve.
Pressure setting (remote control)
Use the optional R100 remote control or the optional Bluetooth dongle to change the pressure set point. Be careful not
to set the pressure below 15 bar (217 psi) if the unit is supplying a satellite – both built-in and external - as this may
compromise the function of the injector.
Stop
The system stops automatically shortly after water is no longer being used like when the operator closes the low
pressure gun or valve.
Leaks
If there are leaks in the system’s non-return valve, pipelines or satellites, the pump will start although there is no
water being used.
Flush injector system (MS5 and MS7)
After each use flush the injector system with warm water to avoid clogging of the injector.
MAINTENANCE
Water filter
Depending on the mains water quality it may be necessary to clean the water filter on a regular basis to prevent the
pump from stopping.
Flow switch
The flow switch does not require maintenance.
Shaft seal
The shaft seal does not require maintenance. Leaks are normally a sign of dry running caused by insufficient water
supply to the pump.
Water non-return valve
Water non-return valves are critical wear parts and should be replaced yearly.