Questions and Answers

  • T
    Terri MartinezAug 19, 2025
    What to do if the System Cleaners unit does not suck up detergent?
    • C
      Connor DixonAug 19, 2025
      If your System Cleaners unit isn't drawing detergent, it could be due to a few reasons. First, make sure the function selector switch is in the correct position. Also, the suction filter or chemical restrictor might be blocked by chemical residue, so clean them. Finally, ensure the suction filter is below the fluid level in the chemical container.
  • R
    ronaldjacksonAug 26, 2025
    What to do if there is no water or insufficient water at the nozzle of my System Cleaners?
    • E
      erika84Aug 27, 2025
      If you're experiencing no water or insufficient water flow at the nozzle of your System Cleaners, ensure that the function selector switch is set to the rinse position. Also, verify that the valve at the end of the hose is fully open.
  • J
    Jennifer DeanSep 3, 2025
    How to fix low water inlet pressure on System Cleaners?
    • A
      areevesSep 3, 2025
      If the low water inlet pressure is illuminated on your System Cleaners, first ensure that the water supply is open. If it is, the water inlet filter may be clogged, so try cleaning it.
  • A
    Alexander FritzNov 11, 2025
    Why is the foam quality poor in my System Cleaners?
    • B
      Brian SandersNov 11, 2025
      Poor foam quality in your System Cleaners unit can stem from several causes: * The air valve may not be open, or the compressor hasn't been started; in this case, open the air valve or start the compressor. * There might be insufficient air supply pressure (Voyager 1, 2, and 4); increase the air supply pressure. * The chemical product might not be designed for foam; switch to a chemical product with a foam booster. * The chemical restrictor may not match the chemical type; change the chemical restrictor to achieve the correct dosing percentage. * The suction filter, dosing valve, or non-return valve could be blocked by chemical residue; clean these components. * There might be insufficient water supply to the unit; ensure the water supply meets the technical specifications. * ...

System Cleaners Voyager Specifications

General IconGeneral
BrandSystem Cleaners
ModelVoyager
CategoryOther
LanguageEnglish

Related product manuals