D3.4
T858/859 Initial Adjustment
M850-00
31/09/98 Copyright TEL
3.3 RF Alignment
3.3.1 Standard Tuning Procedure
T859 Only: For sets with serial numbers following 217262, set RV69 (driver
power level) fully clockwise.
Preset the tuning controls as shown in Figure 3.2.
Set RV63 (front panel power control) fully clockwise.
Key on the drive source.
T859 Only: Adjust CV1 for maximum output.
Adjust CV8 for maximum output.
Adjust CV32 for maximum output.
Adjust CV51 and CV57 for maximum output.
Adjust CV34 and CV35 for maximum output.
Recheck all settings. The power output should exceed:
T858 60W
T859 110W.
T859 Only: For sets with serial numbers following 217262, adjust RV69
(driver power level) until the output power drops to 110W.
Adjust RV63 to reduce the power output to the required level (e.g. 50W for T858,
100W for T859).