General safety precautions for personnel working with the equipment.
Safety precautions related to the handling and operation of equipment.
List of recommended test equipment for reciter fault finding procedures.
Procedures for replacing faulty system interface boards and disposing of old ones.
Initial checks to verify reciter power-up, configuration, alarms, and clock.
Checks to verify receiver synthesizer lock and sensitivity.
Checks to verify exciter synthesizer lock and output specifications.
Tasks to confirm reciter functionality and complete final administration after repair.
Procedure for removing and replacing the system interface board.
Safety precautions for personal and equipment handling during PA fault finding.
List of test equipment required for PA fault finding procedures.
Procedures for replacing faulty boards and disposing of old ones.
Initial checks for PA power-up, configuration, alarms, and LEDs.
Checks to verify PA power-up, transmission, DC supply voltages, and test points.
Checks for DC supply, voltage levels, driver transistor, and output power on the 6W board.
Checks for DC supply, voltage levels, final transistor, and output power on the 60W board.
Checks for DC output voltages and Power Saving operation of the boost regulator board.
Tasks to confirm PA functionality and complete final administration after repair.
Procedure for removing and replacing the 6W board, including recalibration.
Procedure for removing and replacing the 60W board and transistor, including recalibration.
Detailed procedure for replacing the 60W RF power transistor, including recalibration.
Procedure for replacing the control board, including reprogramming and recalibration.
Procedure for replacing the LPF/directional coupler board, including recalibration.
Procedure for removing and replacing splitter/combiner boards.
Procedure for replacing the boost regulator board in 12V PA models.
Safety precautions for personal and equipment handling during PMU fault finding.
List of test equipment required for PMU fault finding procedures.
Procedures for replacing PMU cards and boards, and disposing of faulty items.
Initial checks for PMU power-up, output voltages, and indicator LEDs.
Procedure for testing the auxiliary power supply board's output voltages.
Fault finding procedures for the DC converter without and with microprocessor control.
Test procedures for verifying the AC converter's operation and component resistance.
Safety precautions for personal and equipment handling during PMU disassembly/reassembly.