166 Power Amplifier Fault Finding TB8100 Service Manual
© Tait Electronics Limited September 2006
7. Measure the reverse power analogue voltage at TP102 (or pin 2 of
SK100). The voltage should be less than 0.5V. If it is, go to “Final
Tasks” on page 170. If it is not, replace the LPF/directional coupler
board.
Figure 8.14 Location of the test points and input coupling components on the
LPF/directional coupler board
TP102
TP103
TP104
TP101
TP105
B, C, H, and K bands: C109
L band: R138 and R139
B, C, H, and K bands: C110
L band: R145 and R146
SK100