Configuring the Auxiliary Power Supply and External Reference
continued.
SK: Configure > Base Station > Task Manager
Configure the following
parameters.
1.
Enable the If Base station in run mode Then Enable auxiliary supply
statement. It is important that this supply remains on if powering the
frequency reference as the reference can take some time to stabilise if
power cycled. The Aux power supply will stay on even if the base
station is switched to Standby mode.
Enable this task
manager statement.