16  For your safety
Entity parameters
The Entity Concept allows interconnection of IS/NI 
equipment with associated equipment when the following 
is true:
Ui 
≥ 
Uo, Ii 
≥ 
Io, Pi 
≥ 
Po, Ci 
≤ 
Co, Li 
≤ 
Lo, and Li/Ri 
≤
 Lo/Ro.
The installation must be in accordance with the following 
standards:
■
National Electrical Code (NEC), ANSI/NFPA 70, Arti-
cles 504 and 505
■
Canadian Electrical Code (CEC) Part I, CAS C22.1
■
ANSI/ISA-RP12.06.01
■
EN/IEC 60079-25
■
relevant local regulations.
TP9300/TP9400 IS/NI radios have the following entity 
parameters.
Radio accessory port:
Radio battery port:
■
Uo 7.2 V
■
Io 0.42 A
■
Po 1.3 W
■
Co 1.97 
μ
F
■
Lo 100 
μ
H
■
Lo/Ro 20 
μ
H/
Ω
■
Ui 8.4 V
■
Ii IIA: 2.9 A
 
IIC: 1.9 A
■
Um 9.0 V  (charging)
■
Ci 1.2 
μ
F
■
Li 5.7 
μ
H