7-3. Handling of thread breakage
The machine will stop automatically. Besides, the thread breakage indicator lamp will be lit or blinking in red.
Code No.291 or No.293 will be also displayed on the operation panel.
Restart the embroidery by the following procedure.
(1) Thread the needle, or change the under thread (bobbin case).
(2) Perform Frame Back by some stitches for repair stitches.
When starting the machine, repair stitches will be performed from the position where Frame Back is
stopped.
Lit: The upper thread has broken. (No. 291)
Blinking: The under thread has broken. (No. 293)
Thread breakage indicator lamp
Threader (accessory)
Bobbin case
Attaching to rotary hook