3. Maintenance instructions
3.8.3 General guidelines for oil change intervals for mobile use
For recommended oil change intervals, please see the table below.
Operating temperature of the compressor can be seen in temperature gauge.
Note! If wrong oil type has been used or oil circuit is varnished, please contact an authorized distributor of Gardner
Denver for oil circuit cleaning instructions.
Recommended oil change intervals
Running temperature of
the compressor
AEON 3000 oil change interval
AEON 9000 SP oil change
interval
70–87°C 500 hours 1 000 hours
88–92°C 500 hours 1 000 hours
93°C 300 hours 500 hours
Specific AEON lubricants are recommended for use in this equipment. Other lubricants will cause:
shortened life time of oil filter, oil separating cartridges and oil
varnishing and blockage of oil circuit
increased oil consumption
excessive oil carryover and compressor damage
Do not mix different types of oil