13.3 Biamp System Parameters
Parameter Unit/Name Low Section High Section
Gain (dB) 0 -7
Delay (ms) 0.169 0
Polarity Positive Positive
HPF â Freq (Hz) 40.1 1650
Slope (dB/oct) 24 24
Filter Shape Butterworth Linkwitz Riley
LPF Freq (Hz) 1390 Thru
Slope (dB/oct) 24 NA
Filter Shape Linkwitz Riley NA
Freq (Hz) 62.5 8000
Level (dB) +7 +1.3
Type Parametric Parametric
PEQ 1 ââ
Q / Bandwidth 2.5 / 0.3969 2.5 / 0.3969
Freq (Hz) 327 12500
Level (dB) -2 -3
Type Parametric Parametric
PEQ 2
Q / Bandwidth 1 / 1.000 6.7 / 0.1487
Freq (Hz) 926 NA
Level (dB) +4 NA
Type Parametric NA
PEQ 3
Q / Bandwidth 7.6 / 0.1324 NA
Freq (Hz) 1020 NA
Level (dB) +6 NA
Type Parametric NA
PEQ 4
Q / Bandwidth 2.0 / 0.5 NA
Freq (Hz) NA NA
Level (dB) NA NA
Type NA NA
PEQ 5
Q / Bandwidth NA NA
ââ Note : When using the V15 with subs, set HPF on LF section @ 80 100Hz
(24dB/oct LR) and omit PEQ1 (on LF only)
PEQ 1 (on LF only) may also be omitted when using the V15 as a floor monitor.