EasyManua.ls Logo

Tapeswitch PRSU/4 - PRSU;5 Electrical Overview

Tapeswitch PRSU/4
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Copyright (2021) All rights reserved. Changes, which serve technical improvements are reserved.
5
PRSU Series, Operating Instructions Manual (Revision 1.0)
PRSU/5 Electrical Overview
The PRSU/5 can be operated with an input voltage of 115VAC. This model features three
normally-open safety relays that are triggered by the “Sensor Monitoring” terminals (S11,
S12, S21, S22). This model also features an additional normally-closed auxiliary relay
(not for safety use).
Terminals
Description
A1
Power input (115V
AC
)
A2
Power input (115V
AC
)
13, 14
Safety Relay #1
23, 24
Safety Relay #2
33, 34
Safety Relay #3
41, 42
Auxiliary Relay (Non-Safety)
S33, S34
RESET Mode Control
S11, S12
Sensor Connection
S21, S22
Sensor Connection
Table 3: Device Terminals (PRSU/5)