TASCAM MD-CD1
Owner’s Manual
49
13 – Data settings / service data
Data communication settings
By connecting a PC through its RS-232C terminal to
the MD-CD1 through its CONTROL I/O (RS-232C)
terminal, the two units can be linked for data
exchange. Use the following options on the SERIAL
sub-menu of the CD menu to perform their respective
settings.
BAUD RATE
Sets the communication speed of the keyboard.
4800 / 9600 / 19200 / 38400 bps can be selected.
Default: 19,200
LENGTH
Communication word length can be set to either 7 or
8 bits.
Default: 8 bits
PARITY
Communication parity can be set to NON, EVEN or
ODD.
Default: NON
STOP BIT
The data stop bit can be set to either 1 or 2.
Default: 1
Viewing service data
You can view service data via the following items in
the SYSTEM submenu of the CD menu.
CD P_TIME
The total CD playback time is shown.
MD P_TIME
The total MD playback time is shown.
MD R_TIME
The total MD recording time is shown.
2ReMD-CD1.fm 49 ページ 2004年11月5日 金曜日 午前7時35分