9
Filling the fresh water tank
Dosing:
Dosing examples:
Dosage cup application
Pre-cleaning
Attention:
Max. permissible water temperature
60 °C/140 °F.
Diversey recommends using cold water
since hot water will adjust to the floor tem-
perature as soon as it is in contact with the
floor. Thus there are no advantages to us-
ing hot water.
• The machine must be switched off (main switch).
• Put your hand into the opening be-
tween tank cover and tank.
Palms upwards.
• Open the tank cover until the support engages in the tank
wall.
• Remove the dosage aid.
• Fill the fresh water tank with water.
Maximum filling level (page 5).
• Tip the tank cover back into its original position and press
it down until it locks.
Attention:
Wear gloves, goggles and appropriate
(protective) working clothes when han-
dling chemical products!
Notice:
Use chemical products recommended by
Diversey only and always observe the
product information.
Caution:
Using unsuitable products (e.g. products
containing chlorine, acids or solvents) may
cause harm to health and severe damage
to the machine.
Notice:
For a precise dosage, use the scale in the
dosage cup.
The filling level mark on the tank corre-
sponds to the mark in the dosage cup. The
type of machine is also noted in the dos-
age cup!
Information on
the package of
the product
Tank capacity Dosage cup
0.5% 1/2 1 x 1/2
MAX 1 x MAX
1% 1/2 1 x MAX (2 x 1/2)
MAX 2 x MAX
• Fill the product you have measured
with the dosage cup into the fresh
water tank.
• Slightly lift the tank cover.
• Push the tank cover support slightly inwards.
• Close the tank cover.
• By pushing gently on the front part of the tank cover you
lock the tank.
Notice:
TASKI offers an automatic dosage feature
as an option. It is possible to mount it addi-
tionally. Please contact your customer ser-
vice.
Attention:
Remove any objects (wooden, metal parts
etc.) from the cleaning surface.
The objects could be catapulted by the ro
-
tating tool, and thereby cause injuries to
people and damage to the environment.
EN