EasyManua.ls Logo

Taski vacumat 12 - Malfunctions; Technical Data

Taski vacumat 12
301 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
Malfunctions
Technical data
Malfunction Possible causes Troubleshooting Page
Machine without function
Machine is switched off
Switch on the ON/OFF switch
68
No power supply
Insert the plug into the mains sock-
et
68
Main cord defect Replace the main cord
Defective ON/OFF switch Contact your service partner
Motor does not turn Contact your service partner
Foam or liquid leaking from the ma-
chine
Float malfunction
Switch off ON/OFF switch.
Check the float to make sure it is
fully functional and repair any fault
Repair any fault
68
Floor remains wetSoiled water is not
vacuumed up
Tank full Empty the tank 68
Fixomat squeegee not correctly ad-
justed
Re-adjust Fixomat squeegee
Replace the blade
68
Poor suction performance
Tank full Empty the tank 68
Filter cloth soiled Clean or replace the filter cloth 68
Filter disc dirty Replace the filter disc 68
Hose or dust nozzle blocked
Remove the blockage
68
Coarse filter soiled
Clean or replace coarse filter
Fixomat squeegee not correctly ad-
justed
Re-adjust Fixomat squeegee
Replace the blade
Machine vacumat 12 vacumat 22 vacumat 22T
Rated voltage 220-240V~ 110-120V~ 220-240V~ 110-120V~ 220-240V~ 110-120V~ AC
Frequency 50-60 60 50-60 60 50-60 60 Hz
Rated power, nominal 1000 850 1000 850 1000 850 W
Dimensions (LxWxH) 39x44x55 39x44x55 39x44x65 39x44x65 90x70x98 90x70x98 Cm
Main cord length 10 10 10 10 10 10 m
Maximum weight of opera-
tional machine
10 10 10.5 10.5 19 19 Kg
Tub capacity wet/dry +/-
5%
12 / 18 12 / 18 22 / 28 22 / 28 22 / 28 22 / 28 L
EN