28
of CH1 (in this case the DL2 LED is yellow);
7_ to program transmitters into the third channel, repeat procedure from point 1 using CH1 and CH2
buttons at the same time (DL2 will turn on red);
8_ to exit the learning mode without memorising a code, press button CH1 or CH2 briey.
If the maximum number of radio controls is reached (30), the LED DL2 will begin to ash
rapidly for about 3 seconds but without performing memorisation.
REMOTE PROGRAMMING BY MEANS OF T-4RP / K-SLIM-RP / S-2RP / S-4RP (V 4.X)
With the new version of software V 4.X it is possible to carry out the remote self-learning of the new
version of transmitters T-4RP / K-SLIM-RP / S-2RP / S-4RP (V 4.X), that is without pressing the receiver’s
programming buttons.
It will be sucient to have an already programmed transmitter in the receiver in order to start the
procedure of remote programming of the new transmitters. Follow the procedure written on the
instructions of the transmitter T-4RP / K-SLIM-RP / S-2RP / S-4RP (V 4.X).
CANCELLING CODES FROM RADIO CONTROL DEVICES
1_ Keep button CH1 pressed for 3 seconds in order to cancel all the associated radio control devices;
2_ LED DL2 ashes slowly to indicate that the cancellation mode has been activated;
3_ press button CH1 again for 3 seconds;
4_ LED DL2 turns o for approx. 3 seconds and then remains steady to indicate that the code has
been cancelled;
5_ repeat the procedure from point 1 using button CH2 to cancel all the associated radio control
devices;
6_ repeat procedure from point 1 using CH1 and CH2 buttons at the same time to erase all transmitters
programmed into the third channel;
7_ to exit the learning mode without memorising a code, press button CH1 or CH2 briey.
MEMORY CAPACITY
The code memory capacity* can be expanded from 30 to 126, 254 or 1022 codes (transmitters) by replac-
ing the memory cards as follows
(plug them onto J3 connector, see wiring diagram)
:
126 codes Art. 250SM126
254 codes Art. 250SM254
1022 codes Art. 250SM1022
* Control units are supplied with a standard built-in 30-code memory. The memory card for enhancing
the code memory capacity must be ordered separately.
To allow the previously stored codes (max. 30) to be moved to the control unit, it is required to install
a memory card, making sure that the control unit is at that time o and that the memory card is brand
new and therefore completely empty.
When the control unit is restarted, the codes will automatically move to the memory card.
Moving the codes from the control unit to the memory card does not work if on the memory card
used, radio control codes have already been stored and the memory card has been subsequently
erased.
To insert new radio controls, the operation described above shall be repeated.
WARNING: Control unit must be turned OFF to insert / remove a memory card.
RADIO MEMORY RESET:
- keep the CH1 and PROG keys pressed until the green DL1 and orange DL2 leds start ashing rap-
idly. At this point, release the keys and press them again until the LEDs go o, conrming that the
operation is complete (if they are not pressed and you wait, the board returns to normal operation
after about 12 seconds).
HARD RESET (factory setting):
- Keep the CH2 and PROG keys pressed until the green DL1 and the red DL2 LEDs start ashing quickly.
At this point, release the keys and press them again until the DL1, DL2 and DL8 LEDs switch o.
Release the keys; all the LEDs will turn o conrming that the operation is complete. After about
5 seconds the DL2 will start ashing red/green.
If they are not pressed and you wait, the control unit returns to normal operation after 12 seconds.
ENGLISH