Loading...
- Dust tank lter, it is advisable to be changed
at least once a year or every 100 hours of the
appliance’s use.
TO REMOVE THE FILTERS:
- Open the lid containing the EPA lter at the top
of the tank, turn the lter to unlock it, remove
the tank and push the lter up from the bottom
(Fig. 3).
- The motor lter is located inside the cyclone
located in the tank. Remove the tank by pres-
sing the extraction button (B), lift the cyclone
with the handle and remove the sponge lter.
(Fig.4).
- To reassemble the lter, proceed with the abo-
ve instructions, in reverse order.
CLEANING THE ROTARY BRUSH:
- Remove the transparent cover from the top of
the shoe (Fig. 5).
- Lift the brush by the piece located at the end
of it.
- For assembly, insert the brush into the anchor,
align the cover with the tabs on the front and
press until you hear the click.
SUPPLIES
- Supplies can be acquired from distributors
and authorised establishments (such as lters,
etc...) for your appliance model.
- Always use original supplies, designed speci-
cally for your appliance model.
- These supplies are available in specialist
shops.
HOW TO REMOVE THE BATTERIES FROM
THE INTERIOR OF THE DEVICE:
- CAUTION: It is important that the batteries are
fully discharged prior to its withdrawal from the
apparatus.
- CAUTION: the appliance must be disconnec-
ted from the supply mains when removing the
batteries.
TO REMOVE THE BATTERIES, ONCE THE
LIFE OF THE APPLIANCE, PROCEED AS
FOLLOWS:
- Safely remove the battery from its housing by
pressing the battery removal button. (J)