Taylor TX360L - Heating System Troubleshooting; 1. Heater; defroster fan is not turning; 2. Heater; defroster fan is turning, but no warm air is present; 3. Heater; defroster operates in only one speed

Taylor TX360L
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20H-120H-1TX / TXH / TXB 180S - 400L (Rev. 4/23/07)TX / TXH / TXB 180S - 400L (Rev. 4/23/07)
air volume and therefore the filter should beair volume and therefore the filter should be

Heating SyHeating System Troubleshootinstem Troubleshootingg (Illustration 20H-2)(Illustration 20H-2)
PPrroobblleemm CCaauussee CCoorrrreeccttiioonn
1.1. HeHeatater / er / dedefrfrososteterr
fan is not turningfan is not turning
1.1. The The heaheater ter / de/ defrofrostester swr switcitch (Sh (S5)5)
is defective.is defective.
2.2. CirCircuicuit brt breakeaker (Cer (CB1B11 or C1 or CB12B12) is) is
tripped.tripped.
3.3. CirCircuicuit brt breakeaker (er (CB1CB11 or 1 or CB1CB12)2)
keeps tripping.keeps tripping.
4.4. CirCircuicuit brt breakeaker (Cer (CB1B11 or 1 or CB 1CB 12) i2) iss
defective.defective.
5.5. DefDefectective ive relrelay ay (K1(K12 o2 or Kr K13)13)..
6.6. DeDefefectctivive fae fan mn mototoror..
7.7. LooLoose se or bor brokroken wen wireires / s / pluplugs /gs /
pins between any of the compo-pins between any of the compo-
nents.nents.
1.1. RepReplaclace heae heater / ter / defdefrosroster ter swiswitchtch..
2.2. ReReseset cit circrcuiuit brt breaeakekerr..
3.3. CirCircuicuit t is is shoshorterted. d. TTrouroublebleshoshoot,ot,
isolate and repair short.isolate and repair short.
4.4. RepReplaclace e circircuicuit t brebreakeakerr..
5.5. ReReplplacace re relelayay..
6.6. ReReplplacace fe fan an momototorr..
7.7. TTrouroublebleshoshoot, iot, isolsolate aate and rend replaplacece
wire.wire.
2.2. HeHeatater / er / dedefrfrososteterr
fan is turning, butfan is turning, but
no warm air isno warm air is
presentpresent
1.1. The eThe engingine-ne-moumountented shud shut-ot-off ff valvalveve
or air conditioning / heater unitor air conditioning / heater unit
shut-off valve is closed.shut-off valve is closed.
2.2. HeaHeater hter hoseoses kis kinkenked or rd or restestricrictedted..
3.3. DefDefectective eive engingine thne thermermostostat (sat (stuctuckk
open).open).
4.4. LoLow w cocoololanant.t.
5.5. EngEngine ine is nis not aot at opt operaeratinting teg tempempera-ra-
ture.ture.
1.1. OpOpen shen shutut-o-off ff vavalvlve(e(s)s)..
2.2. UnkUnkink oink or remr remove rove restestricrictiotion frn fromom
hoses.hoses.
3.3. RepReplaclace e engengine ine thethermormostastat.t.
4.4. ChChececk ank and fid fill rall radidiatatoror..
5.5. AllAllow eow engingine ene enounough tgh time ime to to reareachch
operating temperature.operating temperature.
3.3. HeHeatater / er / dedefrfrososteterr
operates in onlyoperates in only
one speedone speed
1.1. DefDefectective hive heateater / deer / defrofrostester swir switchtch
(S5).(S5).
2.2. DefDefectective ive relrelay ay (K1(K12 o2 or Kr K13)13)
3.3. LooLoose se or bor brokroken wen wireires / s / pluplugs /gs /
pins between any of the compo-pins between any of the compo-
nents.nents.
1.1. RepReplaclace heae heater / ter / defdefrosroster ter swiswitchtch..
2.2. ReReplplacace re relelayay..
3.3. TTrouroublebleshoshoot, isot, isolaolate and rete and repaipairr..