Teac A-300 - Electrical Checks and Adjustments (Continued); Input Level Checks and Recording Performance Notes

Teac A-300
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4,
Apply
a
400
Hz
signal
at
—19
dB
(86.9
mV)
to
the
LINE
IN
jacks
and
check
for
-2.5
dB
+
3
dB
(411
mV
to
818
mV).
5.
Then
if
the
level
difference
between
channels
is
more
than
2
dB,
adjust
R22
so
that
the
level
difference
become
less
than
2
dB
between
channels.
(Minimum
Input
Level
checks
for
the
LINE
inputs).
6.
Set
the
LINE
controls
to
minimum
and
the
MIC
controls
to
maximum.
7.
Apply
a
400
Hz
signal
at
—67
dB
(346
yV)
to
the
MIC
jacks
and
check
for
2.5
dB
+
3
dB.
(Minimum
Input
Level
checks
for
the
MIC
jack).
8.
Remove
the
MIC
input
and
apply
a
400
Hz
signal
at
~—35
dB
(13.8
mV)
to
the
input
terminals
of
the
DIN
connector
and
check
for
—2.5
dB
+
3
dB.
(Minimum
Input
Level
checks
for
the
DIN
inputs).
9,
For
the
following
test,
set
the
MIC
controls
to
mini-
mum,
remove
the
DIN
connector
and
then
connect
input
signal
to
the
LINE
IN
jacks.
6-3.
RECORDING
PERFORMANCE
NOTE:
1.
Before
marking
any
adjustments
of
the
record-
ing
circuit,
be
sure
that
the
tests
in
the
preceding
performance
sections
have
been
accomplished.
The
preceding
performance
should
be
properly
adjusted,
otherwise
record
calibration
will
be
inaccurate.
2.
The
adjustments
and
checks
for
NORMAL
tape
usually
may
be
omitted
unless
the
technician
wishes
to
confirm
that
they
also
are
within
specifications
except
for
the
sections
where
these
tape
are
designated.
6-3-1.
BIAS
TRAP
ADJUSTMENTS
NOTE:
The
AC
Voltmeter
used
in
this
procedure
must
have
load
impedance
of
1M
ohm
or
more.
1.
Connect
the
AC
Voltmeter
to
the
BIAS
TRAP
test
point.
Load
any
recordable
tape.
3.
Place
the
deck
in
the
REC
PAUSE
mode
with
no
signal
applied.
4.
Adjust
L103/L203
for
a
minimum
reading.
nN
14
6-2-2.
SPECIFIED
LINE
CONTROL
SETTING
Specification:
Specified
input
level:
—9
dB
(275
mV)
10.
Apply
a
400
Hz
signal
at
—9
dB
(275
mV)
to
the
LINE
IN
jacks.
11.
Set
the
LINE
controls
to
obtain
the
reading
of
580
mV
(—2.5
dB)
on
the
AC
Voltmeter.
Then
check
that
OUTPUT
level
on
the
deck
is
—5 dB
+
1
dB
388mV
to
489
mV).
At
this
time,
the
physical
position
of
the
LINE
controls
indicates
the
Specified
LINE
Control
Setting
referred
to
in
subsequent
procedures.
NOTE:
After
this
setting
is
done,
do
not
disturb
the
Speci-
fied
Control
Setting
of
the
LINE
controls
until
the
remaining
checks
and
adjustments
are
com-
pleted.
6-2-3.
VU
METER
CALIBRATION
CHECKS
Specification:
+3
VUt
1
VU
12.
Make
certain
that
indication
on
the
VU
Meter
on
the
deck
is
+3
VU+1
VU.
Preparations:
AC
Voltmeter
Tpd
LI03/L203
Q106/0206
Fig.
6-9
Connection
Switch
Setting:
Pee
ee
eed
Control
Setting:
OUTPUT:
Specified
Setting
(See
6-1-2)
MIC,
LINE:
Minimum