6-3-4.
DISTORTION
CHECKS
Specifications:
CrO2:
2.2%
or
less
NORMAL:
2.5%
or
less
CrO2
1.
Load
a
TEAC
MTT-506
test
tape.
2.
Apply
and
record
a
400
Hz
test
tone
at
—12
dB
(195
mV).
3.
Rewind
and
play
this
recorded
section.
4.
Read
the
indicated
value
on
the
distortion
analyzer.
NORMAL
5.
Repeat
the
“CrO2”
procedure,
with
the
following
ex-
ceptions.
BIAS/EQ
switches:
NORMAL
Test
tape:
MTT-501
6-3-5.
FREQUENCY
RESPONSE
-OVERALL—
CrO2
Tape
1.
Connect
the
deck
and
the
test
equipments
as
shown
in
Fig.
6-10.
2.
Load
aTEAC
MTT-506
test
tape.
Apply
and
record
a
test
signal
at
-42
dB
(6.15
mV).
4,
With
the
simultaneous
record/playback
function,
make
sure
the
readings
on
the
AC
voltmeter
are
within
the
response
limits.
5.
In
case
of
any
deviation
in
the
high
frequency
range
of
the
response
limits,
clean
the
heads
and
do
the
L104/
L204.
Ww
NORMAL
Tape
6.
Repeat
the
“CrO2”
procedure,
with
the
following
ex-
ceptions.
BIAS/EQ
switches:
“NORMAL”
position
Test
tape:
MTT-501
TEST
TAPE:
MTT-506
DOLBY
NR:
OUT
+4
|
|
2
I
©
RESPONSE
IN
dB.
-3
|
=a
SK
63KY
TOK
12.5K
SOK
8K
Fig.
6-13
Overall
Frequency
Response
Limits
(for
BIAS/EQ:CrO2)
i
FS
40
50
63-100
125
400500
1K
FREQUENCY
IN
Hz
16
OSCILLOSCOPE
Preparations:
DISTORTION
ANALYZER
OSCILLATOR
under
TEST
Fig.
6-12
Connection
Switch
Setting:
BIAS
DOLBYNR
|
MONITOR
Control
Setting:
OUTPUT:
Specified
Setting
(See
6-1-2)
LINE:
Specified
Setting
(See
6-2-2)
MIC:
Minimum
Preparations:
Connection:
See
Fig.
6-10.
Switch
Setting:
BIAS
DOLBYNR
|
MONITOR
Control
Setting:
OUTPUT:
Specified
Setting
(See
6-1-2)
LINE:
Specified
Setting
(See
6-2-2)
MIC:
Minimum
i
+4
+3
Bitz
z
gy
O
2
g-2
|
ra
r
aa
|
I
if
4050
63
100
125
400
S00
BK
6.3K
¥
10K
.
SOK
BK
FREQUENCY
IN
Hz
Fig.
6-14
Overall
Frequency
Response
Limits
(for
BIAS/EQ:NORMAL)