TASCAM MD-CD1 RS-232C Protocol Specification
9 TEAC Corporation
READY
Puts the controlled device in PLAY-READY mode or RECORD-READY mode.
Command 14
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 invalid The command will be ignored in the case of this data.
ILLEGAL will not be transmitted.
0 1 Ready On
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].