TASCAM MD-CD1 RS-232C Protocol Specification
14 TEAC Corporation
SYNC REC LEVEL PRESET
Sets the Sync Rec Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The SYNC REC MODE setting is made by the command "SYNC REC SELECT [38]."
Command 28
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Preset –24dB
0 1 Preset –30dB
0 2 Preset –36dB
0 3 Preset –42dB
0 4 Preset –48dB
0 5 Preset –54dB
0 6 Preset –60dB
0 7 Preset –66dB
0 8 Preset –72dB
F F Sense Requests that the currently preset level be returned.
If data outside the above range is received, the CD-RW901 will return ILLEGAL [F2].
Return SYNC REC LEVEL RETURN [A8]
TEXT PRESET
Specifies a title for the controlled device of up to 80 single-byte alphabetical or katakana characters.
To obtain the assigned title, transmit the command "TITLE SENSE [59]."
Command 29
Machine ID 0
Data 4 bytes84 Bytes
Description Remarks
Data 1 Tens digit of
specified number
Data 2 Ones digit of
specified number
Data 3 Thousands digit of
specified number
Data 4 Hundreds digit of
specified number
0000
0001 – 0099
Specify the disc title
Specify a track title
Data 5 – Data
84
Title Single-byte alphanumeric characters
If a track number not existing on the disc is specified, the CD-RW901 will transmit ILLEGAL
[F2].
The title is between 0 bytes and 80 bytes. The characters up to the last one before CR will be
used as the specified title.
Return TEXT PRESET ACKNOWLEDGE [A9]