TASCAM MD-CD1 RS-232C Protocol Specification
22 TEAC Corporation
REMOTE/LOCAL SELECT
Enables or disables key operations on the controlled device's own panel.
A return command is returned only if Sense [FF] is specified.
Command 4C
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Remote Only remote operation via RS-232C and wired remote
control will be enabled. Key operations on the device's own
panel will be disabled.
0 1 Local Remote operation and key operations on the device's own
panel will be enabled.
F F Sense Requests that the preset content be returned.
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return REMOTE/LOCAL SELECT RETURN [CC]
PLAY MODE SENSE
Requests that the status of the controlled device's Play mode be returned.
Command 4E
Machine ID 0
Data none
Return PLAY MODE RETURN [CE]
MECHA STATUS SENSE
Requests that the status of the controlled device's mechanism be returned.
Command 50
Machine ID 0
Data none
Return MECHA STATUS RETURN [D0]
ISRC SENSE
Requests that the ISRC of the current track be returned.
Command 53
Machine ID 0
Data none
Return ISRC RETURN [D3]
TRACK No. SENSE
Requests that the current track number be returned.
Command 55
Machine ID 0
Data none
Return TRACK No. RETURN [D5]
DISC STATUS SENSE
Requests that the presence or absence of a disc and the type of disc be returned.
Command 56
Machine ID 0
Data none
Return DISC STATUS RETURN [D6]