TASCAM MD-CD1 RS-232C Protocol Specification
21 TEAC Corporation
SYNC REC SELECT
Specifies the Sync Rec Mode setting of the controlled device.
A return command is returned only if Sense [FF] is specified.
The Sync Rec Level is specified by the command "SYNC REC LEVEL PRESET [28]."
Command 38
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Sync Rec Off
0 1 Sync Rec On
F F Sense Requests that the preset content be returned.
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return SYNC REC SELECT RETURN [B8]
INCR PLAY SELECT
Specifies the Incremental Play Mode of the controlled device.
A return command is returned only if Sense [FF] is specified.
Command 3A
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 INCR Play Off
0 1 INCR Play On
F F Sense Requests that the preset content be returned.
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return INCR PLAY SELECT RETURN [BA]
KEY CONTROL SELECT
Specifies the Key Control Mode of the controlled device.
A return command is returned only if Sense [FF] is specified.
The key control value is set by the command "KEY CONTROL DATA PRESET [2D]."
Command 3D
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Key Control
Off
0 1 Key Control
On
F F Sense Requests that the preset content be returned.
If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return KEY CONTROL SELECT RETURN [BD]