5. Mode Programming:
Program mode function table:
Mode function name Description Default
Setting
1.Running Mode
- Forward with brake, Forward/Reverse,Forward//Reverse
with brake
Fwd/ brake
Fwd/Brake/Rev
(XPS EL)
2.Low voltage protection
2.0V~8.4V --- 0.1V/step 6.3V
3. Dead band
0~30% --- 1%/Step 10%
4. Over heat Cut
On/Off On
5. Reverse Force
1~100% --- 1%/Step, higher value have higher reverse force 90%
6. Brake PWM Frequency
Level 1~4, higher level have higher brake frequency 2
7. Brake force
1~100% --- 1%/Step, higher value have higher brake force 90%
8. Drag Brake
1~100% --- 1%/Step, higher value have higher drag brake
force
9%
2%
(XPS EL)
9. Forward PWM Frequency
Level 1~4, higher level have higher forward frequency 3
10. Punch level
0~100% --- 1%/Step, higher value have more initial punch 0%
11. Power Band
1~100% --- 1%/Step, higher value have higher overall
power band
100%
12. Start RPM
1000~100000 --- 1000/Step, RPM to start the Timing Boost 5000
13. Timing Burst
1~100% --- 1%/Step, how fast achieve the max timing
boost value. Higher value allows faster Timing Boost
70%
14.Timing Boost
1~100% --- 1%/Step, higher value have more advance
Timing, in term to make the motor having higher RPM
0%
15. Turbo Delay
0.1~1s --- 0.1s/Step, higher value with longer time to start
up the turbo function
0.1s
16. Turbo Boost
1~100% --- 1%/Step, higher value have more advance turbo
Timing, in term to make the motor having higher RPM
0%
Notes: The maximum sum value of Turbo Boost and Timing Boost cannot be set more than 100%. For